U values for thermal envelope W/(m2k):

 

walls:

  • external: 0.32
  • very little heated premises: 0.50
  • surfaces in contact with the ground or not heated premises: 0.40

roofs:

  • external: 0.25
  • very little heated premises: 0.35
  • surfaces in contact with the ground or not heated premises: 0.30

windows:

  • external: 1.5
  • very little heated premises: 2.0
  • surfaces in contact with the ground or not heated premises: 2.0

doors:

  • external: 2.0
  • very little heated premises: 2.50
  • surfaces in contact with the ground or not heated premises: 2.5

Skylight:

  • external: 2.7
  • very little heated premises: 2.7

surfaces in contact with the ground or not heated premises: 2.7