Building Code of Australia (Residential Buildings) 2011

Last updated: 5 November 2017

Governance



Development Authority: Commonwealth Government - Australian Building Codes Board



Implementation Authority: State Government - Minister for Planning. Department for Planning, Transport and Infrastructure



Verification Authority: Local Government and the private sector



Enforcement Authority: Local Government



Prescriptive Compliance path



Model


Floor area in relation to a room, means the area of the room measured within the finished surfaces of the walls, incl. areas occupied by built in furniture, fixtures and fittings



Energy Requirements:


Insulation


Class 2



R-Values (m2.K/W) Floor Suspended floor Walls


Climate zone 1 0 1 3.3


Climate zone 2 0 1 3.3


Climate zone 3 0 0 3.3


Climate zone 4 0 0 2.8


Climate zone 5 0 1 2.8


Climate zone 6 0 1 2.8


Climate zone 7 1 1.5 2.8


Climate zone 8 2 2.5 3.8




Class 1



R-Values (m2.K/W) Suspended floor Walls


Climate zone 1 1.5 2.8


Climate zone 2 1 2.8


Climate zone 3 1.5 2.8


Climate zone 4 2.25 2.8


Climate zone 5 1 2.8


Climate zone 6 2.25 2.8


Climate zone 7 2.75 2.8


Climate zone 8 3.25 3.8



Windows


The aggregate air-conditioning energy value attributable to the glazing must be calculated using the method and criteria specified in tables J2.4a &b


Skylights


Total area < 5% of floor area, unless required by health and safety compliance requirements. SHGC and U factors are specified by ratio of shaft index to percentage of floor space. Listed in Table J1.4


Air Leakage


1.5 ACH


Space Heating System


Single occupancy (class 1): Heating and cooling loads for model and reference buildings must be calculated by the specified method and criteria (Vol.2 V2.6.2.2) Multi-occupancy (class 2): Annual energy consumption for air conditioning must be calculated with the specified method and criteria (Vol.1 Tables 2a-2g).


Water Heating System


Greenhouse gas intensity of water heaters must be <100g CO2-e/MJ of the thermal energy load.


Lighting


Multi-occupancy (class 2): Maximum illumination power density is prescribed by space type (Table J6.2a) with adjustments for control devices (Table J6.2b)


Renewable Energy


Heating for domestic services must obtained from an on-site renewable energy source, or reclaimed energy , or a source that has a greenhouse gas intensity <100g CO2J


Compliance Softwares:


All software must comply with the Protocol for House Energy Rating Software 2006.1 (Vol.2) or Building Energy Analysis Software 2006.1 (Vol. 1)



End-uses considered:


Auxiliary devices, Space cooling, Space heating, Water heating, Lighting interior, Ventilation


Resources



Notes



Climate zones


HDD: Heating Degree Days



Max. temp: Average January maximum temperature



Water Vapour Pressure: Average 3pm January Water Vapour Pressure




HDD Max. temp Water Vapour Pressure


Climate zone 1 - ‰¥ 30 °C ‰¥2.1kPa


Climate zone 2 - <30 °C ‰¥2.1kPa


Climate zone 3 - ‰¥ 30 °C ‰¤2.1kPa


Climate zone 4 - ‰¥ 30 °C ‰¤2.1kPa