Design Standard for Residential Buildings 1995

Source: International Energy Agency
Last updated: 16 April 2021

Applicable Building Type(s)

New residential

 

Policy Requirement Level

Mandatory

 

Governance

Development Authority: Ministry of Housing and Urban-Rural Development

Implementation Authority: Local governments

Enforcement Authority: Local governments

 

Energy Requirements:

Insulation

 

U-Values (W/m2.K)

Roof 0.33 - 0.4

Walls 0.33 - 0.48

Floor 0.48

Suspended floor 0.7

Curtain walls 0.7

 

All climate zones