The IEA has discontinued providing data in the Beyond 2020 format (IVT files and through WDS). Data is now available through the .Stat Data Explorer, which also allows users to export data in Excel and CSV formats.
Technical residential handbook for Building Regulations 2004 (Scotland 2011)
Source: International Energy AgencyLast updated: 5 November 2017
Applicable Building Type(s) New residential Policy Requirement Level Mandatory Governance Development Authority: The Scottish Government: Building Standards Division Implementation Authority: Local Authority Verification Authority: Local Authority Enforcement Authority: Local Authority Prescriptive Compliance path Energy Requirements: Insulation U-Values (W/m2.K) Walls Floor Roof All climate zones 0.25 0.2 0.18 Windows U-Values (W/m2.K) Windows All climate zones 1.8 Air Leakage 7 m3/(h.m2) at 50 Pa Space Heating System Mechanical ventilation systems (W/L/s) Specific fan power Intermittent extract ventilation; continuous supply ventilation 0.5 Continuous extract ventilation 0.7 Continuous supply and extract with heat recovery ventilation 1.5 Lighting 75% of fixed light fittings must have a minimum luminous efficacy of 45 lumens/circuit watt Compliance Softwares: SAP (Standardised Assessment Procedure) 2009 End-uses considered: Space heating, Water heating, Lighting interior Performance Compliance path Building performance requirement expressed as carbon emissions (kgCO2/m2) based on equivalent model building Resources Notes Climate zones